Manual 1.10

System Processor MIPS CPU (AR9331, 400MHz) Memory 16 MB Flash/64 MB DDR2 RAM Wireless 802.11 b/g/n I/O 1x Binary input (hardware version >=1.4) 1x Relay output Additional storage SD card (2GB by default) SD card (8G...

IOMOD 4Cs4Vs User Manual

IOMOD 4Cs4Vs Firmware version 2

1. Introduction IOMod 4Cs4Vs is a compact-sized stand-alone power meter for measuring analog AC input signals from low-power current and voltage sensors.  It measures three AC voltages and current phases with additional inputs for neutral/residual voltage and...

25 Cyber security

Manual

WCC Lite is based on the OpenWRT operating system. OpenWrt is described as a Linux distribution for embedded devices. WCC Lite has the same functionality as Linux OS including user management. Basic configuration on WCC Lite can be done using a web-based fron...

15.3 IEC 61850 Client

Manual 15 IEC 61850

WCC Lite can be used as a master station to collect data from IEC 61850 compatible server devices such as protection relays. As relays require fast, secure and responsive interfaces, WCC Lite can be considered as a valid option. For additional security, a user...

15.2 IEC 61850 Server

Manual 15 IEC 61850

WCC Lite can act as an IEC 61850 server to serve data to remote SCADA systems. For example, WCC Lite can be used to acquire data from various protocols (Modbus, IEC 60870-5-103, etc.), this data can be redirected and propagated further to a single or multiple ...

15.1 Introduction

Manual 15 IEC 61850

IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations. It is a part of the International Electrotechnical Commission’s (IEC) Technical Committee 57 reference architecture for electr...

1 Overview

Manual

This document is intended to act as a user manual and explain WCC Lite usage in detail. It is expected the person referring to this manual is experienced in programmable logic controllers (PLC), networking (IPv4, ethernet) and the use of the operating system o...

IOMod Meter User Manual

IOMOD Meter Firmware version 2

1. Introduction IOMod Meter is a compact-sized, stand-alone power meter for measuring analog AC input signals from low-power current and voltage sensors. It measures three phases of AC voltage and current amplitudes and phase shifts. Unlike IOMod 4Cs4Vs IOMod...

Upgrading IOMOD from firmware version 1 to firmware version 2

How To

To upgrade the firmware from version 1 to version 2, the user should first connect the IOMOD via a mini USB as required for IOMODs with older firmware. More information on how to set up an IOMOD device for USB configuration can be found in each IOMOD's manual ...

IOMOD 8DI8DO User Manual

IOMOD 8DI8DO Firmware version 2

1. Introduction   The IOMod 8DI8DO is a compact, standalone digital input and output controller compatible with Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. It is designed for industrial applications that require digital signaling and ...

26.1 Introduction

Manual 1.10 26 SMS Receiver

SMS receiver is a service responsible for command execution that was received via text message. The service is available on WCC Lite with the modem. To use this service a working SIM card is also required. This chapter will describe command types and configura...

IOMOD 8DI4RO User Manual

IOMOD 8DI4RO Firmware version 2

1. Introduction IOMod 8DI4RO is a stand-alone digital input and relay output controller. This device is used for industrial applications where digital signaling is used and robust communication is essential. It is controlled over Modbus, IEC 60870-5-101 or IE...

IOMOD 8AI User Manual

IOMOD 8AI Firmware version 2

1. Introduction IOMOD 8AI is a compact analog input module, designed for industrial applications where reliable digital signaling and robust communication are essential. IOMod 8AI can be used for numerous applications where user needs to log Voltage or Curren...

IOMod 16DI user manual

IOMOD 16DI Firmware version 2

1. Introduction The IOMod 16DI is a compact, standalone digital input controller compatible with Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. It is designed for industrial applications that require digital signaling and robust communication. Th...

IOMod 4RTD User Manual

IOMOD 4RTD Firmware version 2

1. Introduction IOMod 4RTD is a standalone temperature sensor device. Designed to measure temperature over a wide range with high accuracy and repeatability even during frequent heating and cooling cycles. 4RTD is equipped with 4 temperature channels to enabl...

IOMOD 16DI User Manual IEC 60870-5-101

IOMOD 16DI Firmware version 1

Introduction IOMOD 16DI is small sized stand-alone Modbus (RTU) or IEC 60870-5-101 digital input controller. IOMOD is used for industrial applications, where digital signaling is used and robust communication is needed. IOMOD is an ideal solution for applic...

IOMOD 16DI User Manual IEC 60870-5-103

IOMOD 16DI Firmware version 1

Introduction IOMOD 16DI is small sized stand-alone Modbus (RTU) or IEC 60870-5-103 digital input controller. IOMOD is used for industrial applications, where digital signaling is used and robust communication is needed. IOMOD is an ideal solution for applicat...

IOMOD 16DI User Manual Modbus

IOMOD 16DI Firmware version 1

Introduction IOMOD 16DI is small sized stand-alone Modbus (RTU) or IEC 60870-5-103 digital input controller. IOMOD is used for industrial applications, where digital signaling is used and robust communication is needed. IOMOD is ideal solution for application...

26.2 SMS Receiver

Manual 1.10 26 SMS Receiver

There are two types of command signals used in SMS Receivers: System: reboot wcc/reboot modem – when sending a message with text reboot, the device starts rebooting and after successful reload sends back a message to the sender with text  REBOOT OK.  sw...

24 Certificates

Manual

Devices that send unencrypted data are susceptible to attacks which might cause deliberate damage to the user system. Therefore it is highly advised to use cryptography to secure sensitive data. WCC Lite offers means to easily store certificates for their late...