CLMod
CLMod – current loop converter
Isolated Mode Examples
In this mode, THE VINCI EXPERT works as protocol master / slave. Everything that comes to A side, comes out of A side and in reverse – what comes in B side, goes to B side. A side is isolated from B side. Fig.1.5. Now, there is two instances of THE VINCI SOFT...
12 DNP 3.0
Overview
THE VINCI EXPERT is the best choice for applications requiring the highest versatility of physical serial communication interfaces. Commissioning engineers, system integrators and product developers will especially appreciate the possibility to perform wiring ...
Connection To PC
When you connect THE VINCI EXPERT to a computer a normally operating system in hardware should find 4 Virtual Com Ports (VCP). First Com port for communication with SIDE A and Second for communication with SIDE B, as described in the Function scheme. Other VCP...
Functionality
Fiber Optic LIGHT ON/OFF mode button – by pressing this button you can easily convert Fiber Optical channel from Light Off mode to Light On mode. The Light On mode is indicated by a Light On indicator. Fiber optic power can be measured in software. Laser radi...
Application Note
THE VINCI EXPERT can be used in two different modes: Isolated and Non-Isolated. Fig.1.1 • Isolated mode allows user to virtually split device into two, and then use each side separately. This mode is useful when user communicates with devices separately and ...
Non Isolated Mode Examples
In this mode, THE VINCI EXPERT works like analyzer / probe. Everything that comes to A side, comes out of B side and in reverse – what comes in B side, goes to A side. Fig.1.2. In this example, THE VINCI SOFTWARE works as master and device connected to THE V...
Technical Data
Fig.1.7. General Dimensions D91 x 19.6 mm Case 6-seriesAluminum Weight 138g PC USB Connection Mini USB Electrical characteristics Power supply via USB 5V Max. operating current Imax=460mA Min. operating current I...
Benefits of Using Software
• Easily change settings through software; • Measure laser power; • Change RS232 pinout; • Save settings to a file; • Analyze protocols and monitor data; • Upload new firmware into THE VINCI EXPERT device.
Complectation
• THE VINCI EXPERT - serial interface protocol analyzer and universal serial interface converter.• Hard case with figure cut foam for connectors and a pocket for wires. All possible connections and wires are attached: • 2 x 1 meter long cable RJ-45 to RJ-45 •...
Capture packets using tcpdump
Description This article describes how to log packets using tcpdump. Installing tcpdump Before starting, you need to install required packages. Tcpdump and Libpcap. These packages can be found attached to the article. To install, you need to upload the pac...
15 IEC 61850
31 IEC 61850
Introduction IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations. It is a part of the International Electrotechnical Commission’s (IEC) Technical Committee 57 reference architect...
29 IEC 60870-5
Introduction IEC 60870 part 5 is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication pro...
29.2 IEC 60870-5-103
IEC 60870-5-103 The IEC 60870-5-103 protocol is a companion standard for the informative interface of protection equipment. Standard IEC 60870-5-103 was prepared by IEC technical committee 57 (Power system control and associated communications).It is a compan...
29.1 IEC 60870-5-101
The IEC 60870-5-101 protocol is a companion standard for power system monitoring, control associated communications for telecontrol, teleprotection, and associated telecommunications for electric power systems. Standard IEC 608705101 was prepared by IEC te...
29.3 IEC 60870-5-104
IEC 60870-5-104 Master IEC 60870-5-104 protocol (in short IEC 104) is a part of IEC Telecontrol Equipment and Systems Standard IEC 60870-5 that provides a communication profile for sending basic telecontrol messages between two systems in electrical engineeri...
11 DNP 3.0
Introduction DNP3 (Distributed Network Protocol) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies. It was developed for communications between vario...
13 DLMS/COSEM
Introduction IEC 62056 is a set of standards for electricity metering data exchange by International Electrotechnical Commission. The IEC 62056 standards are the international standard versions of the DLMS/COSEM specification. DLMS or Device Language Messag...
30 IEC 62056-21
Introduction IEC 61107 or currently IEC 62056-21, was an international standard for a computer protocol to read utility meters. It is designed to operate over any media, including the Internet. A meter sends ASCII (in modes A..D) or HDLC (mode E) data to a ne...
28 Modbus
Introduction Modbus is a serial communications protocol for use with its programmable logic controllers (PLCs). Modbus has become a de facto standard communication protocol and is now a commonly available means of connecting industrial electronic devices. It ...
13 Modbus
16 Specific protocols
– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...
MV Beacon
12 DNP 3.0
Other devices
Manual 1.8.1
This manual is for software version 1.8.1
IOMOD 8DI4RO
Manual
This manual is for software version 1.8.3
ConMod
ConMod P1Modbus – Meter P1 to Modbus RTU/TCP converter
ConMod Downloads
16 Specific protocols
– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...
15 IEC 61850
13 Modbus
8 Internal web page
WCC Lite is configured via an internal web browser, so no additional software is required.
17 Metering protocols
- DLMS/COSEM - IEC 62056-21 - MBus Serial/TCP - Elgama (Meters based on IEC 62056-21 / 31 protocols)
6 Interfaces
WCC lite supports various interfaces to acquire data and control external circuitry. That includes two serial port interfaces, relay output, digital input, and external cellular connection antenna.
5 Installing the WCC Lite
4 WCC Lite status indication and control
CLMod manual
MV Beacon
CLMod
Lua runner examples
14 IEC 60870-5-10X
20 Programmable logic controller
A programmable logic controller (PLC) is a digital device adapted for control of processes which require high reliability, ease of programming and realtime responses. Such functionality has long since replaced hardwired relays, timers and sequencers which wo...
18 Excel Configuration
Protocol HUB uses the configuration in excel file format. Each sheet represents a specific part of the configuration: Devices contain device lists and protocol-related configurations. Signals contain a list of signals and their options. First-line on ea...
35 MQTT
Introduction MQTT (short for MQ Telemetry Transport) is an open OASIS and ISO standard (ISO/IEC PRF 20922) lightweight, publish-subscribe network protocol that transports messages between devices. The protocol usually runs over TCP/IP, although its variant, M...