Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

650 total results found

Manual[1.6.3]

This manual is for software version 1.6.3

Notes

The Vinci Expert

Copyrights and trademarks Elseta is UAB “Elseta” trademark that identifies UAB “Elseta” manufactured products. All of the products copyright belongs to "Elseta”. These documents and the product properties can not be changed without company “Elseta'” knowledge ...

16 Specific protocols

Manual 1.8.1

– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...

15 IEC 61850

Manual 1.8.1

13 Modbus

Manual 1.8.1

12 DNP 3.0

Manual 1.8.1

Configuring data endpoints

Programmable logic controller (PLC)

To use WCC Lite as a programmable logic controller, it needs to be configured in a particular way. The PLC functionality of the WCC Lite only allows for the use of data which has been configured in the Excel configuration spreadsheet. This has been done for se...

Generating and uploading FORTE logic file

Programmable logic controller (PLC)

After the PLC design is finished and debugged, such design can be compiled into FBOOT file and uploaded to one or multiple devices to be used in production. As application being debuggged is not automatically considered as a default application, one should be ...

Distributed control application

Programmable logic controller (PLC)

IEC 64199 standard introduced requirements for a distributed control. This means that multiple devices can change information between them and make their own decisions based on the data they receive from other sources. This enables distributed applications bet...

Modbus RTU to IEC104 protocol conversion

How To

Description This article describes WCC Lite configuration steps to enable Modbus TCP protocol conversion to IEC 104. First steps Before you begin, make sure you have completed all physical installation work according to the manufacturer's installation ins...

USB Drivers

Tools and software

IOMod series devices has USB port for IO module configuration. Due to be accessible on some of Windows OS devices please find attached drivers.  IOmod-USB-driver-V-COM<- download link.

Driver installation

Tools and software Configuration over USB

Device requires USB drivers to work as virtual com port. First-time connection between device and computer could result in “Device driver software was not successfully installed” error.  Device driver error message User then manually installs drivers by sele...

Features

The Vinci Expert

 Front face                                                                                                                                                  Back face   Power on indicator.                                                                   ...

18 Excel Configuration

Manual 1.8.1

Protocol HUB uses the configuration in excel file format. Each sheet represents a specific part of the configuration: Devices contain device lists and protocol-related configurations. Signals contain a list of signals and their options. First-line on ea...

Overview

The Vinci Expert

THE VINCI EXPERT is the best choice for applications requiring the highest versatility of physical serial communication interfaces. Commissioning engineers, system integrators and product developers will especially appreciate the possibility to perform wiring ...

Connection To PC

The Vinci Expert

When you connect THE VINCI EXPERT to a computer a normally operating system in hardware should find 4 Virtual Com Ports (VCP). First Com port for communication with SIDE A and Second for communication with SIDE B, as described in the Function scheme. Other VCP...

Functionality

The Vinci Expert

Fiber Optic LIGHT ON/OFF mode button – by pressing this button you can easily convert Fiber Optical channel from Light Off mode to Light On mode. The Light On mode is indicated by a Light On indicator. Fiber optic power can be measured in software. Laser radi...

Application Note

The Vinci Expert

THE VINCI EXPERT can be used in two different modes: Isolated and Non-Isolated. Fig.1.1 • Isolated mode allows user to virtually split device into two, and then use each side separately. This mode is useful when user communicates with devices separately and ...

Non Isolated Mode Examples

The Vinci Expert

In this mode, THE VINCI EXPERT works like analyzer / probe. Everything that comes to A side, comes out of B side and in reverse – what comes in B side, goes to A side. Fig.1.2. In this example, THE VINCI SOFTWARE works as master and device connected to THE V...

Technical Data

The Vinci Expert

Fig.1.7. General   Dimensions D91 x 19.6 mm Case 6-seriesAluminum Weight 138g PC USB Connection Mini USB     Electrical characteristics   Power supply via USB 5V Max. operating current Imax=460mA Min. operating current I...

Benefits of Using Software

The Vinci Expert

• Easily change settings through software; • Measure laser power; • Change RS232 pinout; • Save settings to a file; • Analyze protocols and monitor data; • Upload new firmware into THE VINCI EXPERT device.

Complectation

The Vinci Expert

• THE VINCI EXPERT - serial interface protocol analyzer and universal serial interface converter.• Hard case with figure cut foam for connectors and a pocket for wires. All possible connections and wires are attached: • 2 x 1 meter long cable RJ-45 to RJ-45 •...

Isolated Mode Examples

The Vinci Expert

In this mode, THE VINCI EXPERT works as protocol master / slave. Everything that comes to A side, comes out of A side and in reverse – what comes in B side, goes to B side. A side is isolated from B side. Fig.1.5. Now, there is two instances of THE VINCI SOFT...

Capture packets using tcpdump

How To

Description This article describes how to log packets using tcpdump. Installing tcpdump Before starting, you need to install required packages. Tcpdump and Libpcap. These packages can be found attached to the article. To install, you need to upload the pac...

31 IEC 61850

Manual[1.6.2]

Introduction IEC 61850 is an international standard defining communication protocols for intelligent electronic devices at electrical substations. It is a part of the International Electrotechnical Commission’s (IEC) Technical Committee 57 reference architect...

17 Metering protocols

Manual 1.8.1

- DLMS/COSEM - IEC 62056-21 - MBus Serial/TCP - Elgama (Meters based on IEC 62056-21 / 31 protocols)

Protocol
DLMS
Protocol
COSEM
Protocol
IEC 62056-21
Protocol
MBus Serial
Protocol
MBus TCP
Protocol
Elgama

20 Programmable logic controller

Manual 1.8.1

A programmable logic controller (PLC) is a digital device adapted for control of processes which require high reliability, ease of programming and real­time responses. Such functionality has long since replaced hard­wired relays, timers and sequencers which wo...

IOMOD 4Cs4Vs

IOMod 4Cs4Vs is a compact-sized stand-alone power meter used for measuring analog AC input signals from low power current and voltage sensors. It measures three phases of AC voltages and currents with additional input for neutral/residual voltage and current....

IOMOD
4CS4VS
Protocol
IEC 60870-5-103
Protocol
Modbus RTU

ConMod Downloads

Manual 1.7.0

This manual is for WCC Lite software version 1.7.0

CLMod

CLMod – current loop converter

MV Beacon

Other devices

Manual 1.8.1

This manual is for software version 1.8.1

IOMOD 8DI4RO

Manual 1.8.3

This manual is for software version 1.8.3

IOMOD Meter

IOMod Meter is a stand-alone metering measurement module for voltages and currents based on sensors technology with communication support based on Modbus RTU, IEC 60870-5-101, and IEC 60870-5-103 protocols. Designed to measure voltage and current values wit...

IOMOD
Meter
Protocol
IEC 60870-5-103
Protocol
Modbus RTU
Protocol
IEC 60870-5-101

Manual

This manual is for software version 1.9

ConMod

ConMod P1Modbus – Meter P1 to Modbus RTU/TCP converter

16 Specific protocols

Manual 1.7.0

– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...

14 IEC 60870-5-10X

Manual 1.8.1

15 IEC 61850

Manual 1.7.0

13 Modbus

Manual 1.7.0

12 DNP 3.0

Manual 1.7.0

8 Internal web page

Manual 1.7.0

WCC Lite is configured via an internal web browser, so no additional software is required.

6 Interfaces

Manual 1.7.0

WCC lite supports various interfaces to acquire data and control external circuitry. That includes two serial port interfaces, relay output, digital input, and external cellular connection antenna.

5 Installing the WCC Lite

Manual 1.7.0

4 WCC Lite status indication and control

Manual 1.7.0

CLMod manual

CLMod

MV Beacon

Other devices

CLMod

Other devices

Lua runner examples

How To

29 IEC 60870-5

Manual[1.6.2]

Introduction IEC 60870 part 5 is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication pro...