16.5 GINLONG
Overview
Ginlong protocol is used to communicate with Ginlong inverters over serial communication.
GINLONG parameters for Device tab:
Parameter |
Type |
Description |
Required |
Default value (when not specified) |
Range |
|
Min |
Max |
|||||
name | string | User-friendly device name | Yes | |||
description | string | Description of the device | No | |||
device_alias | string | Device alias to be used in configuration | Yes | |||
enable | boolean | Enabling/disabling of a device | No | 1 | 0 | 1 |
protocol | string | Selection of protocol | Yes | Ginlong | ||
baudrate | integer | Communication speed, bauds/s (See values 33.1.2) | No | 9600 | 300 | 115200 |
databits | integer | Data bit count for communication | No | 8 | 6 | 9 |
stopbits | integer | Stop bit count for communication | No | 1 | 1 | 2 |
parity | string | Communication parity option (”none”/”even”/”odd”) |
No | none | ||
flowcontrol | string | Communication device flow control option. (Default: (case-sensitive): ”none”) | No | none | ||
scan_rate_ms | integer | If provided and positive all reads and writes will be executed within the timeframe in miliseconds. | No | 10000 | ||
poll_delay_ms | integer | Minimum time delay in miliseconds to wait before sending any data on port. | No | 200 | ||
timeout_ms | integer | Timeout in milliseconds | No | 2500 | ||
id | integer | Inverter ID | Yes | 0 | ||
device | string | Communication port | Yes | PORT1 | PORT2 |
GINLONG parameters for Signals tab:
Parameter |
Type |
Description |
Required |
Default value (when not specified) |
Range |
|
Min |
Max |
|||||
signal_name | string | User-friendly device name | Yes | |||
device_alias | string | Device alias from a Devices tab | Yes | |||
signal_alias | string | Unique alphanumeric name of the signal to be used | Yes | |||
enable | boolean | Enabling/disabling of an individual signal | No | 1 | 0 | 1 |
log | integer | Allow signal to be logged. | No | 0 | ||
job_todo | boolean | Define tag-function | Yes | |||
tag_job_todo | string | Define tag action that depends on tag function | Yes | |||
number_type | integer | Type of a number (FLOAT, DOUBLE, DIGITAL, etc.) | Yes | |||
pulse_short_time_ms | integer | Time interval for short output pulse to stay active | No | 0 | ||
pulse_long_time_ms | integer | Time interval for long output pulse to stay active | No | 0 |