Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

861 total results found

17 Metering protocols

Manual 1.9.3

- DLMS/COSEM - IEC 62056-21 - MBus Serial/TCP - Elgama (Meters based on IEC 62056-21 / 31 protocols)

Protocol
DLMS
Protocol
COSEM
Protocol
IEC 62056-21
Protocol
MBus Serial
Protocol
MBus TCP
Protocol
Elgama

8.2 Site Layout

Manual[1.6.2]

Site layout It provides the main navigation through the website. Contains the following sections: PROTOCOL HUB: configuration related to data exchange between WCC Lite and other devices. STATUS: system information and diagnostics. SYSTEM: basic syste...

7 Tags

Manual[1.6.2]

Single point Commonly used in storing digital states single point values have only one bit of information. The value of such tags can be either one or zero. On the internal web of WCC Lite states of this type of tags are shown in colored boxes with customisab...

12 SMS sender

Manual[1.6.2]

General SMS sender is a service that lets user configure WCC Lite to send SMS on a set tag trigger.s SMS sender functionality is available since firmware version v1.5.4, of WCC Lite. Configuring SMS sender To configure WCC Lite to use SMS sender user must ...

14 Aurora

Manual[1.6.2]

  Overview The Aurora Protocol is a link layer communications protocol for use on point­to­point serial links. Itis intended for use in high­speed (gigabits/second and more) connections internally in a computeror in an embedded system. It uses either 8b/10b ...

1 Overview

Manual[1.6.2]

This document is intended to act as a user manual and explain WCC Lite usage in detail. It is expected the person referring to this manual is experienced in programmable logic controllers (PLC), networking (IPv4, ethernet) and the use of the operating system o...

2 Hardware and software requirements

Manual[1.6.2]

In order to get the WCC Liteup and running, a PC/Mac is required, capable of running a web browser and an MS Excel compatible spreadsheet editor (e.g. LibreOffice or an online spreadsheet editor such as Google Sheets). A built­in or external Ethernet adapter i...

3 Technical information

Manual[1.6.2]

System Processor ARM CPU (AR9331, 400MHz) Memory 16 MB Flash/64 MB DDR2 RAM Wireless 802.11 b/g/n I/O 1x Binary input (hardware version >=1.4) 1x Relay output Additional storage SD card (2GB by default) SD card (2GB...

8.1 Initial Setup

Manual[1.6.2]

Initial setup WCC Lite comes with static network configuration with its IP set to 192.168.1.1. For initial setup set a static IP address on your computer and connect your network card to the WCC Lite with an ethernet cable. Static IP address setup on Windows...

8.3 Protocol Hub

Manual[1.6.2]

Protocol HUB Protocol HUB section stores configuration for every connected device. You can configure it by importing settings from an Excel file. Configuration In this tab a user can: Import new configuration from Excel file (.xls, .xlsx formats). If an...

IOMod IEC 60870-5-103 Slave firmware change-log

ChangeLog - IOMOD firmware version

Elseta IOMod series devices support's IEC 60870-5-103 Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model.  ...

9 API

Manual[1.6.2]

The firmware of the WCC Lite features a built­in API which is accessible via the web interface. As of version 1.2.11, it does not implement any access restriction features apart from those provided by the firewall functionality. Individual API endpoints can b...

10 SNMP

Manual[1.6.2]

SNMP (Simple Network Management Protocol) is an internet­standard protocol for managing devices on IP networks. SNMP exposes management data in the form of a hierarchy of variables in a MIB (Management Information Base). WCC Lite supports SNMP service which i...

15 Elgama

Manual[1.6.2]

Overview Elgama protocol is used for communications with Elagama elektronika electricity meters. Configuration Available meter types (use number only): 0 ­ EPQM/LZQM 1 ­ EPQS 2 ­ GAMA300 3 ­ GAMA100 4 ­ ITS cl Elgama parameters for Device tab ...

16 SMA NET

Manual[1.6.2]

Overview SMA Net can transfer SMA Data, TCP/IP and many more telegrams due to its multi­protocol capability. Thus, it is the preferred telegram frame in case of new developments. Configuration SMA NET parameters for Device tab Parameter Type Descri...

17 Windlog

Manual[1.6.2]

Overview Windlog protocol is used for communications with Windlog data logger. Configuration Windlog parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min Max name ...

18 At command

Manual[1.6.2]

Overview At command protocol is used for communications with AT Commands. Configuration At command parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min Max name s...

19 SOLPLUS

Manual[1.6.2]

Overview Solplus protocol is used to download inverter data from Solplus inverters using a http client. Configuration Solplus parameters for Device tab Parameter Type Description Required Default value (when not specified) Range ...

IOMod Modbus RTU Slave firmware change-log

ChangeLog - IOMOD firmware version

Elseta IOMod series devices support's Modbus RTU Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model.  ...

IOMod IEC 60870-5-101 Slave firmware change-log

ChangeLog - IOMOD firmware version

Elseta IOMod series devices support's IEC 60870-5-101 Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model.  ...

Protocol
IEC 60870-5-101

16 Specific protocols

Manual 1.9.3

– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...

26 SMS Receiver

Manual 1.9.3

14 IEC 60870-5-10X

Manual 1.9.3

13 Modbus

Manual 1.9.3

12 DNP 3.0

Manual 1.9.3

8 Internal web page

Manual 1.9.3

WCC Lite is configured via an internal web browser, so no additional software is required.

6 Interfaces

Manual 1.9.3

WCC lite supports various interfaces to acquire data and control external circuitry. That includes two serial port interfaces, relay output, digital input, and external cellular connection antenna.

5 Installing the WCC Lite

Manual 1.9.3

4 WCC Lite status indication and control

Manual 1.9.3

IOMOD Utility

Tools and software

8 Internal web page

Manual 1.10

WCC Lite is configured via an internal web browser, so no additional software is required.

15 IEC 61850

Manual 1.10

20 Programmable logic controller

Manual 1.10

A programmable logic controller (PLC) is a digital device adapted for control of processes which require high reliability, ease of programming and real­time responses. Such functionality has long since replaced hard­wired relays, timers and sequencers which wo...

18 Excel Configuration

Manual 1.10

Protocol HUB uses the configuration in excel file format. Each sheet represents a specific part of the configuration: Devices contain device lists and protocol-related configurations. Signals contain a list of signals and their options. First-line on ea...

17 Metering protocols

Manual 1.10

- DLMS/COSEM - IEC 62056-21 - MBus Serial/TCP - Elgama (Meters based on IEC 62056-21 / 31 protocols)

Protocol
DLMS
Protocol
COSEM
Protocol
IEC 62056-21
Protocol
MBus Serial
Protocol
MBus TCP
Protocol
Elgama

16 Specific protocols

Manual 1.10

– Aurora (ABB PV inverters protocol) – PowerOne (ABB PV inverters protocol) – SMA Net (SMA PV inverters protocol) – Kaco (Kaco PV inverters protocol) – Ginlong (Ginlong PV inverters protocol) – Solplus (Solutronic AG PV inverters protocol) – ComLynx (Dan...

14 IEC 60870-5-10X

Manual 1.10

13 Modbus

Manual 1.10

12 DNP 3.0

Manual 1.10

20 GINLONG

Manual[1.6.2]

Overview Ginlong protocol is used to communicate with Ginlong inverters over serial communication. GINLONG parameters for Device tab: Parameter Type Description Required Default value (when not specified) Range Min Max ...