Reading Modbus TCP meter

How To

Description This article describes The Vinci Software configuration steps to read Modbus TCP meter. The Phoenix Contact EM377 meter will be used. Initial Set-Up Before you begin, make sure you have completed all physical meter installation work according ...

16.6 Kaco

Manual[1.6.3] 16 Specific protocols

Overview This protocol is meant to be used by inverters that convert the DC power generated by the photovoltaic (PV) modules into AC power and feed this into the power grid. This protocol handles serial communication parameters (baudrate, databits, stopbits,...

16.4 Delta

Manual[1.6.3] 16 Specific protocols

Overview Delta protocol is used to communicate with Delta inverters over serial communication. Configuration Delta parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min Ma...

23 Certificates

Manual[1.6.3]

Devices that send unencrypted data are susceptible to attacks which might cause deliberate damage to the user system. Therefore it is highly advised to use cryptography to secure the sensitive data. WCC Lite offers means to easily store certificates for their ...

22 Data Export

Manual[1.6.3]

General Various protocols are made to transmit data points as they are generated. This is enough for a lot of systems (e.g. SCADAs) that have their own databases and devices only have to buffer fairly recent messages in case of connection or transmission erro...

21 MQTT

Manual[1.6.3]

Introduction MQTT (short for MQ Telemetry Transport) is an open OASIS and ISO standard (ISO/IEC PRF 20922) lightweight, publish-subscribe network protocol that transports messages between devices. The protocol usually runs over TCP/IP, although its variant, M...

19 WCC Lite internal signals

Manual[1.6.3]

Overview The WCC Lite contains several internal data points for readout and control which can be accessed via the Pooler service. Configuration Devices section In the devices section, only the protocol, scan_rate_ms and poll_delay_ms are to be configured f...

17.2 IEC 62056-21

Manual[1.6.3] 17 Metering protocols

Introduction IEC 61107 or currently IEC 62056-21, was an international standard for a computer protocol to read utility meters. It is designed to operate over any media, including the Internet. A meter sends ASCII (in modes A..D) or HDLC (mode E) data to a ne...

16.5 GINLONG

Manual[1.6.3] 16 Specific protocols

Overview Ginlong protocol is used to communicate with Ginlong inverters over serial communication. GINLONG parameters for Device tab: Parameter Type Description Required Default value (when not specified) Range Min Max ...

16.11 VESTAS

Manual[1.6.3] 16 Specific protocols

Overview Vestas is a protocol used for communication with solar station automation via serial link. Configuration Vestas parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min ...

Testing IOMod 8DI8DO IEC-103

How To

Initial Setup The first thing to do when setting up is to connect the IOMod to the computer using The Vinci Expert to convert from RS485 to USB. You need to connect it like in the diagram depicted below. Connect The Vinci Device to the computer using a mic...

16.10 VBUS

Manual[1.6.3] 16 Specific protocols

Overview Vbus is a protocol used for communication with solar station automation via serial link. Configuration VBUS parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min ...

16.6 KOSTAL

Manual[1.6.3] 16 Specific protocols

Overview Kostal protocol is used to communicate with Kostal devices over serial communication. Configuration Kostal parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min M...

16.7 POWERONE

Manual[1.6.3] 16 Specific protocols

Overview PowerOne protocol is used to communicate with Aurora inverters over serial communication. Serial communication parameters (baudrate, parity, etc.) are handled automatically by the protocol. Configuration PowerOne parameters for Device tab Pa...

16.3 COMLYNX

Manual[1.6.3] 16 Specific protocols

Overview Comlynx protocol is used to communicate with Comlynx inverters over serial communication. Comlynx parameters for Device tab: Parameter Type Description Required Default value (when not specified) Range Min Max ...

1 Overview

Manual[1.6.3]

This document is intended to act as a user manual and explain WCC Lite usage in detail. It is expected the person referring to this manual is experienced in programmable logic controllers (PLC), networking (IPv4, ethernet) and the use of the operating system o...

IEC 60870-5-104

The Vinci Software Protocol Specific

IEC 60870-5-104  is a protocol for power system monitoring and controlling. Mostly used to communication between substations and control centers over Ethernet (Fiber optics, 2/3/4G, ...).IEC 60870-5-104 protocol is an extension of IEC 60870-5-101 protocol with...

IEC 104 Slave Simulator for SCADA System

How To

Initial Setup All you need to do to set up is to be connected to a network from which the SCADA is reachable. Standard settings in the Vinci software are for an RJ-45 cable, but it is configurable using the Hardware tab. When you're connected to the network...

IEC-104 Master SCADA Setup

How To

Initial Setup. First connect to a network from which the IEC104 Slave device is reachable. When you're connected to the network it's time to open The Vinci Software and start configuring the SCADA parameters. The Vinci Expert will simulate the Master (Client)...

16.9 SOLPLUS

Manual[1.6.3] 16 Specific protocols

Overview Solplus protocol is used to download inverter data from Solplus inverters using a HTTP client. Configuration Solplus parameters for Device tab Parameter Type Description Required Default value (when not specified) Range ...