The Vinci Software changelog

v3.1.0.171 - Software release. 2022 June 27.

What's new
  • The improved user experience by asking to save before exiting. Previously every instance was asking to save the log into a file. Now that became optional.
  • License activations - now the software has a license activation feature. All customers having Vinci Expert and Commercial licenses can register their licenses. 

image-1655996914504.jpg

  • Lookup values - now that enables to change in statistics shows commands states names as you prefer.

image-1655996923676.png

  • IEC 60870-5 Commands now have Select Before Operate (SBO) control possibilities.

image-1655996934611.04.48.png

  • Now in IEC 60870-5-103 Master protocol, you can control the startup routine by freely setting Link layer settings.

image-1655996943086.png

  • Now Modbus master supports commands with functions 5, 6, 15, and 16. 

  • Now Modbus master you can send commands from the Tag window directly.

image-1655996963503.39.32.png

  • Added support of many number formats to represent measurements. That works both ways to show values as well convert on commands execution.

image-1655996988333.png

Other improvements
  • NEW: Freemium version is limited to 50 tags.
  • NEW: New Tag saves on the "enter" key press.
  • FIX: Tag Import CSV file headers are now case insensitive and became easier with import/export.
  • FIX: Improved Tag import/export behavior.
  • FIX: removed unnecessary files from the installation folder.
  • FIX: remove a single item from the filter.
  • FIX: enabled the possibility to copy multiple rows from the console tab.
  • IEC 60870-5:
    • NEW: IEC103 now supports the 23rd data type.
    • NEW: added type and number to all commands and indications by the standard.
    • FIX: IEC104 master t3 timer resets after receiving test frame activation.
    • FIX: IEC104 master reconnection issue fixed.
    • FIX: Display warning if Telegram structure doesn’t match with structure Settings.
    • FIX: IEC103 slave doesn’t establish a connection after receiving an ACK.
  • Modbus:
    • FIX: issue commands with registers higher than 255.
    • FIX: Modbus Start button was not responding to clicks after importing tags.


v3.1.0 changelog

Important changes:

  • The improved user experience by asking to save before exiting. Previously every instance was asking to save the log into a file. Now that became optional.
  • License activations - now the software has a license activation feature. All customers having Vinci Expert and Commercial licenses can register their licenses. 
  • Lookup values - now that enables to change in statistics shows commands states names as you prefer.

  • IEC 60870-5 Commands now have Select Before Operate (SBO) control possibilities.

  • Now in IEC 60870-5-103 Master protocol, you can control the startup routine by freely setting Link layer settings.

  • Now Modbus master supports commands with functions 5, 6, 15, and 16. 

  • Now Modbus master you can send commands from the Tag window directly.
  • Added support of many number formats to represent measurements. That works both way to show values as well convert on commands execution.

Other improvements:

  • NEW: Freemium version is limited to 50 tags.
  • NEW: New Tag saves on the "enter" key press.
  • FIX: Tag Import CSV file headers are now case insensitive and became easier with import/export.
  • FIX: Improved Tag import/export behavior.
  • FIX: removed unnecessary files from the installation folder.
  • FIX: remove a single item from the filter.
  • FIX: enabled the possibility to copy multiple rows from the console tab.
  • IEC 60870-5:
    • NEW: IEC103 now supports the 23rd data type.
    • NEW: added type and number to all commands and indications by the standard.
    • FIX: IEC104 master t3 timer resets after receiving test frame activation.
    • FIX: IEC104 master reconnection issue fixed.
    • FIX: Display warning if Telegram structure doesn’t match with structure Settings.
    • FIX: IEC103 slave doesn’t establish a connection after receiving an ACK.
  • Modbus:
  • FIX: issue commands with registers higher than 255.
  • FIX: Modbus Start button was not responding to clicks after importing tags.

v3.0.1.119 - Bugfix version release. 2022 February 22.


v3.0.1 changelog

Important updates and bug fixes:

  •  Modbus TCP stability (avoid a crash);
  •  Modbus format of registers conversion into various formats has bad interpretation;
  •  IEC 60870-5 protocols command COT-x fixed;
  •  IEC 60870-5 some data types become hidden because they cannot be in use by protocol description;
  •  IEC 60870-5 time sync fixed;
  •  IEC 60870-5-103 and 104 GI fixed;

v3.0.0.98 - Software release. 2022 January 12.


v3.0.0 initial version