Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

869 total results found

8.1 Initial Setup

Manual[1.6.3] 8 Internal web page

WCC Lite comes with a static network configuration with its IP set to 192.168.1.1. For initial setup set a static IP address on your computer and connect your network card to the WCC Lite with an ethernet cable. 8.1.1 Static IP address setup on Windows 1. Pr...

14.5 IEC 60870-5-104 Master

Manual[1.6.3] 14 IEC 60870-5-10X

IEC 60870-5-104 protocol (in short IEC 104) is a part of IEC Telecontrol Equipment and Systems Standard IEC 60870-5 that provides a communication profile for sending basic telecontrol messages between two systems in electrical engineering and power system auto...

12.1 Introduction

Manual[1.6.3] 12 DNP 3.0

DNP3 (Distributed Network Protocol) is a set of communications protocols used between components in process automation systems. Its main use is in utilities such as electric and water companies. It was developed for communications between various types of data...

14.6 IEC 60870-5-104 Slave

Manual[1.6.3] 14 IEC 60870-5-10X

IEC 60870-5-104 Slave is designed not to lose data acquired from Master protocols. The data that arrives from Master protocols is stored in the cache. This data is checked every second to manage further data sending. The data that leaves IEC 60870-5-104 Slave ...

14.3 IEC 60870-5-101 Slave

Manual[1.6.3] 14 IEC 60870-5-10X

Configuring datapoints (slave) To use IEC 60870­-5­-101 Slave in WCC Lite, it has to be configured via an Excel configuration. This configuration contains two Excel sheets where parameters have to be filled in ­Devices and Signals. IEC 60870-­5-­101 slave pa...

18.4 Uploading configuration

Manual[1.6.3] 18 Excel Configuration

As of WCC Lite version v1.4.0, there are three separate ways to import the configuration: import an Excel file via the web interface, generate compressed configuration files and later upload them via the web interface; or generate compressed configuration file...

18.3 Mathematical functions

Manual[1.6.3] 18 Excel Configuration

Signal value might require some recalculation or signal update prior to being sent. Understandably, existing columns in Excel configuration like multiply, add, bit_select might not be flexible enough. To overcome these limitations, symbolic mathematical expres...

18.2 Optional parameters for signals

Manual[1.6.3] 18 Excel Configuration

The signals sheet contains all signals linked to devices. Each signal is defined in a single row. The Signal list can be split into multiple sheets. Each sheet name may start as Signals. Required attributes These attributes are mandatory for every configured...

18.1 Devices sheet

Manual[1.6.3] 18 Excel Configuration

Devices sheet contains all devices to be configured on the gateway. Each row represents one device and its settings. Following options are required for each device: name - Name of the device. Used for representation only. description - A short description ...

14.4 IEC 60870-5-103 Master

Manual[1.6.3] 14 IEC 60870-5-10X

The IEC 60870-5-103 protocol is a companion standard for the informative interface of protection equipment. Standard IEC 60870-5-103 was prepared by IEC technical committee 57 (Power system control and associated communications). It is a companion standard for...

8.2 Site layout

Manual[1.6.3] 8 Internal web page

It provides the main navigation through the website. Contains the following sections: PROTOCOL HUB: configuration related to data exchange between WCC Lite and other devices. STATUS: system information and diagnostics. SYSTEM: basic system settings such...

14.2 IEC 60870-5-101 Master

Manual[1.6.3] 14 IEC 60870-5-10X

The IEC 60870-­5-­101 protocol is a companion standard for power system monitoring, control associated communications for telecontrol, teleprotection, and associated telecommunications for electric power systems. Standard IEC 60870-­5­-101 was prepared by IEC ...

14.1 Introduction

Manual[1.6.3] 14 IEC 60870-5-10X

IEC 60870 part 5 is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication profile for sendi...

8.8 Logout

Manual[1.6.3] 8 Internal web page

To log out of the device graphical user interface a logout button in the interface’s upper right corner should be pressed. A user is automatically disconnected after ten minutes of inactivity. This ensures that the device would not be suspect to any delibera...

8.7 Network

Manual[1.6.3] 8 Internal web page

The page shows information about current interface status, its configurations, provides various interface, network properties configuration capabilities and contains the following subsections:• INTERFACES: shows information about current interface status, al...

8.6 Services

Manual[1.6.3] 8 Internal web page

Services tab shows the services of the device and contains the following subsections: Services tab shows the services of the device and contains the following subsections: TELEMETRY AGENT: device telemetry sending to a remote server; IPSEC: encrypted vi...

8.5 System

Manual[1.6.3] 8 Internal web page

System The system tab includes various properties, configurations, and settings of the system and contains the following pages: • SYSTEM: properties and settings of the system.• ADMINISTRATION: settings of the administration for various services.• SOFTWARE: ...

8.4 Status

Manual[1.6.3] 8 Internal web page

Overview System System section in the status tab shows basic information about the current status of the system.Hostname: The label that is used to identify the device in the network.Model: Model of the device.Firmware version: Current firmware version.Kerne...

8.3 Protocol Hub

Manual[1.6.3] 8 Internal web page

Protocol HUB section stores configuration for every connected device. You can configure it by importing settings from an Excel file. Configuration In this tab a user can: Import new configuration from Excel file (.xls, .xlsx formats). If any errors in t...

12.2 DNP 3.0 Master

Manual[1.6.3] 12 DNP 3.0

Default group and variation sets are used to send commands. If slave devices support different groups and variations, they can be adjusted in Excel configuration. For more information check section Excel configuration. Configuring datapoints To use DNP3 Mast...