16.2 Aurora
Overview The Aurora Protocol is a link layer communications protocol for use on point-to-point serial links. Itis intended for use in highspeed (gigabits/second and more) connections internally in a computeror in an embedded system. It uses either 8b/10b...
16.13 M-Bus
Overview M-Bus or Meter-Bus is a protocol for the remote reading of water, gas, or electricity meters. M-Bus is also usable for other types of consumption meters, such as heating systems or water meters. The M-Bus interface is made for communication on two wi...
14.6 IEC 60870-5-104 Slave
Since firmware version 1.8.3, multiple signals with different data types can have same ioa address. IEC 60870-5-104 Slave is designed not to lose data acquired from Master protocols. The data that arrives from Master protocols is stored in the cache. This dat...
14.5 IEC 60870-5-104 Master
IEC 60870-5-104 protocol (in short IEC 104) is a part of IEC Telecontrol Equipment and Systems Standard IEC 60870-5 that provides a communication profile for sending basic telecontrol messages between two systems in electrical engineering and power system auto...
14.4 IEC 60870-5-103 Master
The IEC 60870-5-103 protocol is a companion standard for the informative interface of protection equipment. Standard IEC 60870-5-103 was prepared by IEC technical committee 57 (Power system control and associated communications). It is a companion standard for...
14.3 IEC 60870-5-101 Slave
Configuring datapoints (slave) To use IEC 60870-5-101 Slave in WCC Lite, it has to be configured via an Excel configuration. This configuration contains two Excel sheets where parameters have to be filled in Devices and Signals. IEC 60870-5-101 slave pa...
14.2 IEC 60870-5-101 Master
The IEC 60870-5-101 protocol is a companion standard for power system monitoring, control associated communications for telecontrol, teleprotection and associated telecommunications for electric power systems. Standard IEC 60870-5-101 was prepared by IEC t...
14.1 Introduction
IEC 60870 part 5 is one of the IEC 60870 set of standards which define systems used for telecontrol (supervisory control and data acquisition) in electrical engineering and power system automation applications. Part 5 provides a communication profile for sendi...
16.14 KOSTAL
Overview Kostal protocol is used to communicate with Kostal devices over serial communication. Configuration Kostal parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min M...
16.12 Windlog
Overview Windlog protocol is used for communications with the Windlog data logger. Configuration Windlog parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min Max n...
16.3 COMLYNX
Overview Comlynx protocol is used to communicate with Comlynx inverters over serial communication. Comlynx parameters for Device tab: Parameter Type Description Required Default value (when not specified) Range Min Max ...
16.11 VESTAS
Overview Vestas is a protocol used for communication with solar station automation via serial link. Configuration Vestas parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min ...
16.10 VBUS
Overview Vbus is a protocol used for communication with solar station automation via serial link. Configuration VBUS parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min ...
16.9 SOLPLUS
Overview Solplus protocol is used to download inverter data from Solplus inverters using a HTTP client. Configuration Solplus parameters for Device tab Parameter Type Description Required Default value (when not specified) Range ...
16.8 SMA NET
Overview SMA Net can transfer SMA Data, TCP/IP and many more telegrams due to its multiprotocol capability. Thus, it is the preferred telegram frame in case of new developments. Configuration SMA NET parameters for Device tab Parameter Type Descri...
16.7 POWERONE
Overview PowerOne protocol is used to communicate with Aurora inverters over serial communication. Serial communication parameters (baudrate, parity, etc.) are handled automatically by the protocol. Configuration PowerOne parameters for Device tab Pa...
16.6 Kaco
Overview This protocol is meant to be used by inverters that convert the DC power generated by the photovoltaic (PV) modules into AC power and feed this into the power grid. This protocol handles serial communication parameters (baudrate, databits, stopbits,...
16.5 GINLONG
Overview Ginlong protocol is used to communicate with Ginlong inverters over serial communication. GINLONG parameters for Device tab: Parameter Type Description Required Default value (when not specified) Range Min Max ...
16.4 Delta
Overview Delta protocol is used to communicate with Delta inverters over serial communication. Configuration Delta parameters for Device tab Parameter Type Description Required Default value (when not specified) Range Min Ma...
2 Hardware and software requirements
In order to get the WCC Lite up and running, a PC/Mac is required, capable of running a web browser and an MS Excel compatible spreadsheet editor (e.g. LibreOffice or an online spreadsheet editor such as Google Sheets). A builtin or external Ethernet adapter ...