8.4 Status
Overview System System section in status tab shows basic information about current status of the system.Hostname: The label that is used to identify the device in the network.Model: Model of the device.Firmware version: Current firmware version.Kernel versio...
34 Programmable logic controller
A programmable logic controller (PLC) is a digital device adapted for control of processes which require high reliability, ease of programming and realtime responses. Such functionality has long since replaced hardwired relays, timers and sequencers which wo...
1 Overview
This document is intended to act as a user manual and explain WCC Lite usage in detail. It is expected the person referring to this manual is experienced in programmable logic controllers (PLC), networking (IPv4, ethernet) and the use of the operating system o...
14 Aurora
Overview The Aurora Protocol is a link layer communications protocol for use on pointtopoint serial links. Itis intended for use in highspeed (gigabits/second and more) connections internally in a computeror in an embedded system. It uses either 8b/10b ...
12 SMS sender
General SMS sender is a service that lets user configure WCC Lite to send SMS on a set tag trigger.s SMS sender functionality is available since firmware version v1.5.4, of WCC Lite. Configuring SMS sender To configure WCC Lite to use SMS sender user must ...
7 Tags
Single point Commonly used in storing digital states single point values have only one bit of information. The value of such tags can be either one or zero. On the internal web of WCC Lite states of this type of tags are shown in colored boxes with customisab...
IOMod Modbus RTU Slave firmware change-log
Elseta IOMod series devices support's Modbus RTU Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model. ...
IOMod IEC 60870-5-103 Slave firmware change-log
Elseta IOMod series devices support's IEC 60870-5-103 Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model. ...
IOMod IEC 60870-5-101 Slave firmware change-log
Elseta IOMod series devices support's IEC 60870-5-101 Slave protocol. This firmware can be used for IOMod series devices: IOMod 8DI8DO v1.x, IOMod 16DI v1.x, IOMod 8AI v1.x, IOMod 4RTD v1.x, IOMod HT v1.x This version does not support IOMod 4Cs4Vs model. ...
6 WCC Lite interfaces
WCC lite supports various interfaces to be acquire data and control external circuitry. That includes two serial port interfaces, relay output, digital input and external cellular connection antennae. Serial port interfaces WCC Lite WCC Lite has 2 serial por...
8.5 System
System System tab includes various properties, configuration, and settings of the system and contains the following pages: • SYSTEM: properties and settings of the system.• ADMINISTRATION: settings of the administration for various services.• SOFTWARE: setti...
5 Installing the WCC Lite
Mounting To mount the device:1. Secure the top of the mounting clip onto a DIN rail.2. Push the bottom of a device forward to fix the clip in place. To dismount the device:1. Pull red colored clip downwards (found at the bottom side of the DIN rail).2. Pull ...
4 WCC Lite status indication and control
Status indication Reset button The reset button is located on the front panel of WCC Lite, to access it, remove a transparent front panel cover. Different time lengths of button pressing call different behaviour. Pressing time Description Indication ...
33.3 Uploading configuration
As of WCC Lite version v1.4.0 there are three separate ways to import the configuration: import an Excel file via web interface, generate compressed configuration files and later upload them via web interface; or generate compressed configuration files and upl...
33.2 Signals Configuration
The signals sheet contains all signals linked to devices. Each signal is defined in a single row. The Signal list can be split into multiple sheets. Each sheet name may start as Signals. Required attributes These attributes are mandatory for every configured...
33.1 Devices configuration
Protocol HUB uses configuration in excel file format. Each sheet represents a specific part of configuration: Devices contains device list and protocol related configuration. Signals contains a list of signals and their options. First line on each sheet...
8.8 Logout
To log out of the device graphical user interface a logout button in interface’s upper right corner should be pressed. A user is automatically disconnected after ten minutes of inactivity. This ensures that the device would not be suspect to any deliberate d...
8.7 Network
The page shows information about current interface status, its configurations, provides various interface, network properties configuration capabilities and contains the following subsections:• INTERFACES: shows information about current interface status, al...
8.6 Services
Introduction Services tab shows the services of the device and contains the following subsections: Services tab shows the services of the device and contains the following subsections: TELEMETRY AGENT: device telemetry sending to a remote server; IPSEC:...
2 Hardware and software requirements