**Parameter**
| **Type**
| **Description**
| **Required
| **Default value**
(when not specified)
| **Range**
|
Min
| Max
|
name | string | User-friendly device name | Yes | | | |
description | string | Description of the device | No | | | |
device\_alias | string | Device alias to be used in configuration | Yes | | | |
enable | boolean | Enabling/disabling of a device | No | 1 | 0 | 1 |
protocol | string | Selection of protocol | Yes | | Delta |
baudrate | integer | Communication speed, bauds/s | No | 9600 | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 |
databits | integer | Data bit count for communication | No | 8 | 6 | 9 |
stopbits | integer | Stop bit count for communication | No | 1 | 1 | 2 |
parity | string | Communication parity option
(”none”/”even”/”odd”) | No | none | | |
flowcontrol | string | Communication device flow control option. (Default: (case-sensitive): ”none”) | No | none | | |
scan\_rate\_ms | integer | If provided and positive all reads and writes will be executed within the timeframe in miliseconds. | No | 10000 | | |
poll\_delay\_ms | integer | Minimum time delay in miliseconds to wait before sending any data on port. | No | 200 | | |
timeout\_ms | integer | Timeout in milliseconds | No | | 0 | 60000 |
id | integer | Inverter ID | Yes | 0 | | |
device | string | Communication port | Yes | | PORT1 | PORT2 |