**Parameter**
| **Type**
| **Description**
| **Required
| **Default value**
(when not specified)
| **Range**
|
Min
| Max
|
name | string | User-friendly device name | Yes | | | |
description | string | Description of a device | No | | | |
device\_alias | string | Alphanumeric string to identify a device | Yes | | | |
enable | boolean | Enabling/disabling of a device | No | 1 | 0 | 1 |
protocol | string | Protocol to be used. | Yes | | Windlog
|
device | string | Communication port | Yes | | PORT1 | PORT2 |
baudrate | integer | Communication speed, bauds/s | No | 115200 | 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600,115200 |
databits | integer | Data bit count for communication | No | 8 | 6 | 9 |
stopbits | integer | Stop bit count for communication | No | 1 | 1 | 2 |
parity | string | Communication parity option | No | none | none, even, odd | |
flowcontrol | string | Communication device flow control option. | No | none | none | |
timeout\_ms | integer | Timeout of waiting for incoming request in
miliseconds | Yes | | 0 | 60000 |
serial\_close\_delay | integer | Delay before closing serial port | No | 400 | | |